Shell and Tube Heat Exchangers |
Hot Fluid |
Cold Fluid |
U [W/m2C] |
|
Heat Exchangers | Water | Water | 800 - 1500 |
| Organic solvents | Organic Solvents | 100 - 300 |
| Light oils | Light oils | 100 - 400 |
| Heavy oils | Heavy oils | 50 - 300 |
| Reduced crude | Flashed crude | 35 - 150 |
| Regenerated DEA | Foul DEA | 450 - 650 |
| Gases (p = atm) | Gases (p = atm) | 5 - 35 |
| Gases (p = 200 bar) | Gases (p = 200 bar) | 100 - 300 |
| | | |
Coolers | Organic solvents | Water | 250 - 750 |
| Light oils | Water | 350 - 700 |
| Heavy oils | Water | 60 - 300 |
| Reduced crude | Water | 75 - 200 |
| Gases (p = atm) | Water | 5 - 35 |
| Gases (p = 200 bar) | Water | 150 - 400 |
| Gases | Water | 20 - 300 |
| Organic solvents | Brine | 150 - 500 |
| Water | Brine | 600 - 1200 |
| Gases | Brine | 15 - 250 |
| | | |
Heaters | Steam | Water | 1500 - 4000 |
| Steam | Organic solvents | 500 - 1000 |
| Steam | Light oils | 300 - 900 |
| Steam | Heavy oils | 60 - 450 |
| Steam | Gases | 30 - 300 |
| Heat Transfer (hot) Oil | Heavy oils | 50 - 300 |
| Heat Transfer (hot) Oil | Gases | 20 - 200 |
| Flue gases | Steam | 30 - 100 |
| Flue gases | Hydrocarbon vapours | 30 -100 |
| | | |
Condensers | Aqueouos vapours | Water | 1000 - 1500 |
| Organic vapours | Water | 700 - 1000 |
| Refinery hydrocarbons | Water | 400 - 550 |
| Vapours with some non condensibles | Water | 500 - 700 |
| Vacuum condensers | Water | 200 - 500 |
| | | |
| Vaporisers | | |
| Steam | Aqueouos solutions | 1000 - 1500 |
| Steam | Light organics | 900 - 1200 |
| Steam | Heavy organics | 600 - 900 |
| Heat Transfer (hot) oil | Refinery hydrocarbons | 250 - 550 |
|
|
|
|
Air Cooled Exchangers |
Process Fluid |
|
U [W/m2C] |
|
| Water | | 300 - 450 |
| Light organics | | 300 - 700 |
| Heavy organics | | 50 - 150 |
| Gases | | 50 - 300 |
| Condensing hydrocarbons | | 300 - 600 |
|
|
| | | |
| | | |
Immersed coils |
Coil |
Pool |
U [W/m2C] |
|
Natural circulation | Steam | Dilute aqueouos solutions | 500 - 1000 |
| Steam | Light oils | 200 - 300 |
| Steam | Heavy oils | 70 - 150 |
| Aqueouos solutions | Water | 200 - 500 |
| Light oils | Water | 100 - 150 |
| | | |
Agitated | Steam | Dilute aqueouos solutions | 800 - 1500 |
| Steam | Light oils | 300 - 500 |
| Steam | Heavy oils | 200 - 400 |
| Aqueouos solutions | Water | 400 - 700 |
| Light oils | Water | 200 - 300 |
|
|
| | | |
| | | |
Jacketed vessels |
Jacket |
Vessel |
U [W/m2C] |
|
| Steam | Dilute aqueouos solutions | 500 - 700 |
| Steam | Light organics | 250 - 500 |
| Water | Dilute aqueouos solutions | 200 - 500 |
| Water | Light organics | 200 - 300 |
|
|